Manufacturer Info
Morningstar's Ground Fault Protection Device (GFPD) prevents current from following any unintended paths during a ground fault. Other ground fault detection/interruption products break the bond to the grounded conductor. When this occurs, not only is the earth bond compromised, but the battery and DC loads can also be left ungrounded and floating. For a negatively grounded system this means that the negative side of the battery and loads can float to negative Voc in relation to ground and the positive side can float to (negative Voc + Vbat). Morningstar's GFPD better isolates the array from the battery and loads, while maintaining the bond to ground. Compatible with:
- TriStar MPPT 600V
- TriStar MPPT
- ProStar MPPT
- DataSheets / EN | Download
- DataSheets / ES | Download
- DataSheets / DE | Download
- DataSheets / FR | Download
- Operations Manual / GFPD-600V | Download
- Operations Manual / GFPD-150V | Download
- Disconnects both the positive and negative conductor and completely isolates PV source circuits
- Trips at 300mA compared to 1A for alternative solutions
- Provides design flexibility to accommodate large and small array configurations
- Uses high quality breaker solutions rather than fuses which are problematic to replace at remote sites
- Works like a traditional AC GFI
- Maintains the integrity of earth bond for battery and loads
- Does not require an extra warning label at the battery per U.S. National Electric Code requirements
- Makes it easier to locate and troubleshoot ground faults
- Powered via the pv system’s battery
- Equipped with both visual and audible alarms
- Built to support both single controller and multiple controller systems
- When the earth bond is not broken, Morningstar’s GFPD will only shut off affected controllers
- All loads will continue to operate safely with the battery remaining bonded to ground
- Multiple controllers and GFPDs can be added on an as-needed basis
Other Products in This Category
Morningstar, RM-1, Remote Meter For use with: PS-MPPT, PS(Gen3), SS-Duo, SS-MPPT or Classic SureSine Inverter
$141.38 $108.75
$141.38 $108.75
Morningstar, RB-BMS, ReadyBMS Block: A snap-in ReadyBlock enabling full communications
$301.14 $231.65
$301.14 $231.65
Morningstar, TS-M-2, TriStar Digital Meter For use with: TS-45, TS-60, TS-MPPT-30, TS-MPPT-45 & TS-MPPT-60
$173.51 $133.47
$173.51 $133.47
Morningstar, RTS, Remote Temperature Sensor ** NOTE: RTS included with all TS-MPPT units
$57.62 $44.33
$57.62 $44.33
Morningstar, MSC, PC Meterbus Adapter For use with: PS-MPPT, SS-Duo, SS-MPPT or Classic SureSine Inverter
$62.05 $47.73
$62.05 $47.73
Morningstar, EMC-1, Ethernet Meterbus Converter For use with: Classic Suresine Inverter, ALL MPPT, ALL TS, PS (Gen 3) or SS-Duo
$239.31 $184.09
$239.31 $184.09
Morningstar, GFPD-600V, Ground Fault Protection Device for 600 volt For use with: All TS-MPPT-600V series
$646.16 $497.04
$646.16 $497.04
Morningstar, RB-RELAY, ReadyRelay Block: A snap-in ReadyBlock enabling signaling via two dry
$197.44 $151.88
$197.44 $151.88
Morningstar, TS-M-2-600V, TriStar 600V Digital Meter For use with: TS-MPPT-600V units only
$177.50 $136.54