Outback Power, OBFRS-01, 150VDC, 12A, Imo Fireraptor Rapid Shutdown Unit
Manufacturer Info
Solar Panel Rapid Shutdown & Alarm
MANUAL OPERATION: Manual shutdown is initiated within less than 1 second of operation by pressing the emergency pushbutton on the Emergency Rapid Shutdown Switch (Part no FRS-ESWx). The Emergency Switch can be conveniently located at ground level for easy access or multiple switches can be installed in different multi-level building zones.
EXTERNAL POWER LOSS: Disconnection of the external AC supply, by whatever means, causes automatic remote operation of the Emergency Rapid Shutdown Switch and panel shutdown.
TEMPERATURE RISE TRIGGER: Automatic shutdown occurs if the temperature sensor onboard the FireRaptor detects an ambient temperature rise above 85C (185F). The FRS-01 shuts down only the panel(s) connected to it upon sensing an ambient temperature rise above 85C (185F). Provided the temperature does not exceed 92C (198F), the unit will re-engage the panel(s) if the temperature drops back below 85C (185F), otherwise a manual reset of the Emergency Switch is required.
Inverter Compatibility: The FireRaptor operates in the same way as an isolator/disconnect switch but is located at solar panel level. Like an isolator/disconnect, the FireRaptor is compatible with all string inverters and does not affect their operation or performance in any way.
- Manual Panel Shutdown to 0V Operated from Ground Level
- Automatic Panel Shutdown to 0V at >85C (185F) Temperature
- Automatic Panel Shutdown to 0V on External Power Loss
- Hardwire or Mobile Communication Alarm Signalling
- Compliant with NEC 2014 & NEC 2017
- Suitable for New Installations or Retro-Fit
- FireRaptor OBFRS-01 Specifications | Download
- FireRaptor OBFRS-01 Installation Guide | Download
- FireRaptor Quality Assurance Report | Download
- Outback FireRaptor Module Level Application Note | Download
MANUAL OPERATION: Manual shutdown is initiated within less than 1 second of operation by pressing the emergency pushbutton on the Emergency Rapid Shutdown Switch (Part no FRS-ESWx). The Emergency Switch can be conveniently located at ground level for easy access or multiple switches can be installed in different multi-level building zones.
EXTERNAL POWER LOSS: Disconnection of the external AC supply, by whatever means, causes automatic remote operation of the Emergency Rapid Shutdown Switch and panel shutdown.
TEMPERATURE RISE TRIGGER: Automatic shutdown occurs if the temperature sensor onboard the FireRaptor detects an ambient temperature rise above 85C (185F). The FRS-01 shuts down only the panel(s) connected to it upon sensing an ambient temperature rise above 85C (185F). Provided the temperature does not exceed 92C (198F), the unit will re-engage the panel(s) if the temperature drops back below 85C (185F), otherwise a manual reset of the Emergency Switch is required.
Inverter Compatibility: The FireRaptor operates in the same way as an isolator/disconnect switch but is located at solar panel level. Like an isolator/disconnect, the FireRaptor is compatible with all string inverters and does not affect their operation or performance in any way.
Other Products in This Category
Outback Power, PNL-GFDI-80D, PV Ground-Fault Detector Interrupter 80 Amp 150 VDC two pole panel mount
$164.67 $126.67
$164.67 $126.67
Outback Power, PNL-75-DC-RT, Relay-trip breaker, 75 Amp, 300 VDC, single pole, two panel-mount spaces
$109.78 $84.45
$109.78 $84.45
Outback Power, OBCATV-3, 3' (1 meter) 300 volt rated OutBack communications cable with RJ45 connectors
$14.20 $10.92
$14.20 $10.92
Outback Power, FW-SBUS, Shunt Bus allows up to four high current cable connections on same side of DC shunt - includes two 3/8" bolts and mounting screws. Solid brass rated for 500 Amps.
$48.67 $37.44
$48.67 $37.44