A built-in AC bypass switch with full system current capability, and a DC disconnect breaker for safe and easy isolation for servicing of the inverter and/or battery bank.
Battery to inverter/charger DC disconnect breaker (250 Amps).
Inverter AC input overcurrent protection breakers.
DIN mount AC and DC breakers for quick and easy operation.
A500A/50mV DC shunt installed for easy connection to battery status monitor.
Enclosure and components are UL/CSA certified and designated for indoor use.
Configurations available for both single 120 and 230 VAC, 120/240 VAC and 3-Phase systems.
DC negative, positive and ground busbars for DC loads and PV arrays included.
Mounting provided for DIN rail DC load/disconnect breakers.
Integrates directly with Victron Energy’s 3,000 and 5,000 MultiPlus and Quattro inverter/chargers.
Knockouts for inverter/charger and battery cables, PV in/out, DC panel mount breakers.
Victron Electrical Panel Installation and Service Manual | Download
Compatibility
The VE Panel (VEP) is designed for the 3kVA and 5kVA MultiPlus and Quattro inverter/chargers.